Effectivity: 915 i A Series
Edition 0 / Rev. 0
BRP-Rotax Page 2-5
December 01 2017
EGT-Split EGT- Split is the difference between the actual highest EGT val-
ue of the actual lowest EGT value.
Parameter Min. Max.
EGT-Split at
> 3 Liter/hour (Fuel
consumption).
–
200 °C (392 °F)
EGT-Split at
< 3 Liter/hour (Fuel
consumption).
–
500 °C (932 °F)
Ambient
temperature
Parameter Min. Max.
Ambient temperature
at ground idle, start
procedure and warm
up.
- 20 °C (- 4 °F) 50 °C (120 °F)
Ambient temperature
at normal operation
- 40 °C (- 40 °F) 50 °C (120 °F)
Fuel pressure
Parameter Min. Max.
Fuel pressure at fuel
rail
2.9 bar (42 psi) 3.1 bar (45 psi)
Acceptable
Fuel pressure
exceedance
(max. 3 sec.)
2.5 bar (36 psi) 3.5 bar (51 psi)
NOTE
Fuel pressure exceedance only allowed after power setting
change.