73-00-00
page 50
May 01/2007
Effectivity 914 Series
Edition 1 / Rev. 0
d02623
BRP-Rotax
Maintenance Manual
â–  CAUTION: Ensure that the total slip-on length is used for all
pressure connecting lines and that the clamps are fixed
securely.
In addition, all lines must be routed in such a way that scuffing and kinks
are avoided. See 73-00-00 sec. 3.4.5 and 73-00-00 sec. 3.4.6.
Reconnect plug connections to temperature sensors and throttle
potentiometer.
Check that the plug connections are attached securely.