T-Max® Manager/Plus and T-Max®3A/F/I User’s Guide Page 35
1) Press the Up and Down Button on the T-Max®3A/F/I until the session time is displayed. If
the display shows a 0, and you want to count down from the maximum time, press the down
button.
2) Press and release the Start/Stop button to start the session.
If a delay other than 0 is entered, the delay will count down. A period on the lower right
corner of the display will flash rapidly. When the session starts, the period will flash at a
once per second rate.
10.2 Pausing a Session
To pause the session press the Start/Stop button. The flashing period on the lower right corner
of the display will stop flashing. The session time will continue to count down.
To restart the session, press the Start/Stop button on the T-Max®3A/F/I. The period on the
lower right corner of the display will resume flashing.
10.3 Canceling a Session.
To cancel a session, press the Start/Stop button to pause the session then press the Up button.
The display will show a solitary 0.
11. OTHER FEATURES and OPTIONS
11.1 Clean Room
Once the session time has elapsed, the display will show two solid periods only. This is an
indication that the room needs to be cleaned. To clear the clean room indication, press and
hold the Up button on the T-Max®3A/F/I in the tanning room until the two periods disappear
and a “0” appears. To disable the clean room feature, set parameter 9 to a 0 (Refer to Section
5.2.6 if you are using the T-Max® Mgr/Plus manually, Section 6.3.5 if you are using ADNET,
or Section 8.2 if you want to disable Clean Room at the T-Max®3A/F/I).
If the Clean Room and Cool Down Modes are enabled, the clean room will be displayed
ADNET will show Dirty, but the Cool Down time will be shown counting down. If the room is
cleaned before the cool down time has elapsed or if the clean room is disabled, a solid period
will be displayed on the lower center on the T-Max®3A/F/I and On the T-Max® Mgr. The
ADNET screen will show FAN with the cool down time counting down. You cannot start a
session until the cool down time has elapsed.
If the Clean Room and Cool Down Modes are enabled, the clean room will be displayed. If
the room is cleaned before the cool down time has elapsed or if the clean room is disabled, a
solid period will be displayed on the lower center on the T-Max®3A/F/I. The display and
ADNET will read FAN and the light on the left of the T-Max® Mgr/Plus will flash green. You
cannot start a session until the cool down time has elapsed.