Sam4s ER-260EJ/256EJ OP Manual v1.20 Integrated Payment Appendix • 209
DataTran Diagnostic
Use only with Datacap Support as necessary to troubleshoot Datatran issues.
1. Turn the control lock to the Z position.
2. Press 5 and CASH to select the Datatran Function menu.
3. Press 8 and CASH; The message “DIAG NUMBER 0” will display.
4. Press the 0 key and then CASH to print a list of diagnostic options:
5. Reselect the Diagnostic option. The message “DIAG NUMBER” will again display.
6. Enter the number of the diagnostic test you wish to perform and press CASH. The report
will print.
DATE 5/05/2017 THU TIME 10:34
*** DATATRAN SELF TESTS ***
1 IPTRAN VERSION
4 CREDIT MID SETTINGS
10- IP ADDRESS
11- DNS TEST
15- PARAM LOAD
40- EEPROM DATA
41- RESET SEQKUENCE NUMBER
CLERK 1 000096 00000