9-4 EB 8355-2 EN
Servicing
9.5 Removing the solenoid
valve
Î Order number for cover for solenoid
valveopening:1400-6949
Î See Fig.9-2
1. Unscrew bracket with plate (1). Remove
the connecting cable of the solenoid
valvefromterminals81/82.
2. Unscrewthetwoscrews(7)thatarenot
sealed with paint and remove the sole-
noid valve with its connecting cable.
3. Place the rubber gasket on the spigot of
the cover and screw it into the housing.
4. Screw on the bracket with plate (1).
9.6 Periodic inspection and
testing of the positioner
We recommend inspection and testing ac-
cording to Table 9-1 at the minimum.