EasyManuals Logo

Samsung DVM S Series User Manual

Samsung DVM S Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
Selecting installation location
Decide the installation location, with the consideration of the following conditions, under user’s approval.
f Place where hot discharge air or noise from the outdoor unit may not disturb the neighbor (Especially in residential areas,
keep the operation hours in mind.)
f Place where structure can bear the weight and vibration of the outdoor unit.
f Place with at surface where rainwater does not settle or leak.
f Place where it is not exposed to strong wind.
f Well ventilated place with sucient service place for repairs and maintenance. (Discharge duct can be purchased
separately)
f Place where you can connect the refrigerant pipes between indoor and outdoor units within allowable distance.
f Place where it allows easy waterproong and draining work for the condensation water generated from the outdoor unit
during heating operation.
f Place where there is no risk of inammable gas leakage.
f Place where there is no direct inuence of snow or rain.
f Do not install the product in a place where it will be directly exposed to sea breeze.
- Consult an installation expert (or company) since you will need to take extra anti-corrosion measures if you need to
install the product in a place where it can be exposed to direct sea breeze. (You have to remove dusts and salinity on
the heat exchanger and apply designated rust inhibitor more than once a year.)
Sea
Sea breeze
Outdoor
unit
Outdoor
unit
Caution when installing the product in seashore
- When installing the product in seashore, make sure to install it behind a structure (such as building) that can block the
sea breeze or install protection wall around the outdoor unit.
- Make sure to install the product in a place where it allows smooth drainage.
Protection wall should be constructed with a solid material that
can block the sea breeze and the height and width of the wall
should be 1.5 times larger than the size of the outdoor unit. (You
must secure more than 700mm of space between the protection
wall and the outdoor unit for air circulation.)
Sea
Sea breeze
Outdoor
unit
Protection wall
Outdoor unit
Sea
Sea breeze
Outdoor
unit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung DVM S Series and is the answer not in the manual?

Samsung DVM S Series Specifications

General IconGeneral
RefrigerantR410A
Operating Temperature Range (Cooling)-5°C to 48°C
Piping Length (Total)1000m
Inverter TechnologyYes
TypeVRF System
Compressor TypeInverter Scroll Compressor
Energy EfficiencyHigh Efficiency
ControlCentralized Control, Individual Control
Indoor Unit OptionsCassette, Duct, Wall Mount, Ceiling