4.Troubleshooting
ErrorCode
S5–3111
Errormessage
UISystemFailure#S5-3111:Turnoffthenon.
Symptom
CommunicationerrorbetweenmainboardandOPEboardhasoccurred.
Troubleshootingmethod
1)RemovetheOPEhubboardcover.
2)CheckiftheOPEAssycableisconnectedtotheOPEhubboardcorrectly.
3)IftheconnectionisOK,replacetheOPEAssy.
4)IftheOPEAssyisOK,replacetheOPEhubboard.