-69-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
2 Fan3 Initial Volt
Fan Start Voltage (0.1V)
0-255 60
3 Fan4 Initial Volt 0-255 40
4 Fan5 Initial Volt 0-255 40
5 Fan6-8 Initial Volt 0-4095 1845
8 Cooling Time Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 60
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (1V) (Read only) 0-255 ---
1 Lamp Vol Threshold Threshold Voltage (1V) 30-90 30
2 Fan1 Speed Gain Fan Speed Ad Gain (0.1V) 0-1500 0
257 Fan Setting at Dimmer
0 Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10 1
258 Fan Control Range Setting (for Lamp2)
0 High Fan4 Min (LAMP2)
Fan Spinning (Min/Max) (rpm)
0000 - 9990 5200 3256 5200 5200
1 High Fan4 Max (LAMP2) 0000 - 9990 5200 3256 5600 5600
2 High Fan5 Min (LAMP2) 0000 - 9990 3256 5200 3256 3256
3 High Fan5 Max (LAMP2) 0000 - 9990 3256 5200 3656 3656
4 Normal Fan4 Min (LAMP2) 0000 - 9990 4424 2880 4424 4424
5 Normal Fan4 Max (LAMP2) 0000 - 9990 4424 2880 4824 4824
6 Normal Fan5 Min (LAMP2) 0000 - 9990 2880 4424 2880 2880
7 Normal Fan5 Max (LAMP2) 0000 - 9990 2880 4424 3280 3280
8 Eco Fan4 Min (LAMP2) 0000 - 9990 3640 2504 3640 3640
9 Eco Fan4 Max (LAMP2) 0000 - 9990 3640 2504 4040 4040
10 Eco Fan5 Min (LAMP2) 0000 - 9990 2504 3640 2504 2504
11 Eco Fan5 Max (LAMP2) 0000 - 9990 2504 3640 2904 2904
259 Fan Air Pressure Setting
0 Press Source Range Low
Pressure Sensor Control Range (AD)
0-1024 645
1 Press Source Range High 0-1024 825
2
Press Fan Add Range High(lamp
in)(High)
Add Spinning (Lamp Intake fan)
0 - 5000 160
3
Press Fan Add Range Low(lamp
in)(High)
0 - 5000 640
4
Press Fan Add Range High(no
lamp in)(High)
Add Spinning (without Lamp Intake fan)
0 - 5000 720
5
Press Fan Add Range Low(no
lamp in)(High)
0 - 5000 1432
6
Press Fan Add Range High(lamp
in)(Normal)
Add Spinning (Lamp Intake fan)
0 - 5000 200
7
Press Fan Add Range Low(lamp
in)(Normal)
0 - 5000 1552
8
Press Fan Add Range High(no
lamp in)(Normal)
Add Spinning (without Lamp Intake fan)
0 - 5000 720
9
Press Fan Add Range Low(no
lamp in)(Normal)
0 - 5000 1432
10
Press Fan Add Range High(lamp
in)(Eco)
Add Spinning (Lamp Intake fan)
0 - 5000 96
11
Press Fan Add Range Low(lamp
in)(Eco)
0 - 5000 896
12
Press Fan Add Range High(no
lamp in)(Eco)
Add Spinning (without Lamp Intake fan)
0 - 5000 720
13
Press Fan Add Range Low(no
lamp in)(Eco)
0 - 5000 1432
14 Temp A Warning (High)(Highland) Temp A Error at High 0 - 100 40
15 Temp B Warning (High)(Highland) Temp B Error at High 0 - 100 56
16 Temp C Warning (High)(Highland) Temp C Error at High 0 - 100 51
17
Temp A Warning
(Normal)(Highland)
Temp A Error at Normal 0 - 100 40
18
Temp B Warning
(Normal)(Highland)
Temp B Error at Normal 0 - 100 56
19
Temp C Warning
(Normal)(Highland)
Temp C Error at Normal 0 - 100 51
20 Temp A Warning (Eco)(Highland) Temp A Error at Eco 0 - 100 40
21 Temp B Warning (Eco)(Highland) Temp B Error at Eco 0 - 100 56
22 Temp C Warning (Eco)(Highland) Temp C Error at Eco 0 - 100 51