-70-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
260 Auto Calibration (Common) * Auto calibration
0 Execute Calibration
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0
3 AutoWait Waiting time 1 - 20 3
4 CHECK - Tolerance Tolerance of Offset 1 - 255 4
5 Time out wait Wait Time until Time out [sec.] 1 - 255 20
261 Auto Calibration (RGB) PW392-AFE MDL <10bits>
0 OFFSET AREA H START Black Level Acq. Area H Start 0 - 1000 975
1 OFFSET AREA V START Black Level Acq. Area V Start 0 - 1000 500
2 GAIN AREA H START White Level Acq. Area H Start 0 - 1000 25
3 GAIN AREA V START White Level Acq. Area V Start 0 - 1000 500
4 Image AREA H WIDTH Black/White Level Area Width 0 - 4095 13
5 Image AREA V HEIGHT Black/White Level Area Height 0 - 4095 9
6 OFFSET Target Black Level Adj target 0 - 1023 20
7 OFFSET Tolerance Black Level Adj telerance 1 - 1023 1
8 GAIN Target White Level Adj target 0 - 1023 955
9 GAIN Tolerance White Level Adj telerance 1 - 1023 1
10 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 8
262 Auto Calibration (CVBS/SVIDEO) PW392-AFE MDL <10bits>
0 Y Image Area Start X Y Image Area H Start 0 - 1000 20
1 Y Image Area Start Y Y Image Area V Start 0 - 1000 200
6 Image Area H WIDTH Image Level Acq. Width 0 - 4095 8
7 Image Area V HEIGHT Image Level Acq. Height 0 - 4095 9
8 Y Target Level Y Level Adj target 0 - 1023 875
11 Gain Tolerance Level Adj Tolerance 1 - 255 1
12 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 2
264 Auto Calibration (YCbCr) PW392-AFE MDL <10bits>
0 Y-OFFSET AREA H START Y - Offset Acq Area H Start 0 - 1000 925
1 Y-OFFSET AREA V START Y - Offset Acq Area V Start 0 - 1000 500
2 CB - OFFSET AREA H START CB - Offset Acq. Area H Start 0 - 1000 925
3 CB - OFFSET AREA V START CB - Offset Acq. Area V Start 0 - 1000 500
4 CR - OFFSET AREA H START CR - Offset Acq. Area H Start 0 - 1000 925
5 CR - OFFSET AREA V START CR - Offset Acq. Area V Start 0 - 1000 500
6 Y - GAIN AREA H START Y 0 - 1000 50
7 Y - GAIN AREA V START 0 - 1000 500
8 CB - GAIN AREA H START 0 - 1000 800
9 CB - GAIN AREA V START 0 - 1000 500
10 CR - GAIN AREA H START 0 - 1000 700
11 CR - GAIN AREA V START 0 - 1000 500
12 Image AREA H WIDTH YCBCR Level Acq. Width 0 - 4095 13
13 Image AREA V HEIGHT YCBCR Level Acq. Height 0 - 4095 9
14 Y - OFFSET TARGET 0 - 1023 4
15 CB OFFSET TARGET 0 - 1023 512
16 CR OFFSET TARGET 0 - 1023 512
17 Y - GAIN TARGET 0 - 1023 810
18 CB - GAIN TARGET 0 - 1023 894
19 CR - GAIN TARGET 0 - 1023 894
20 OFFSET Tolerance OFFSET Adj Tolerance 1 - 255 1
21 GAIN Tolerance GAIN Adj Tolerance 1 - 255 1
22 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 8
280 Auto PC Adjust
0 AutoPCAdjustEnable
Auto PC Operation with the un-supported signal in.
0: Enable 1: Disable
0 - 1 0
1 Frequency Step TotalDot Search Step 0-3 1
2 Frequency Threshold TotalDot Match 0 - 10 5
3 Fine Phase
Phase after Total Dot Adj.
0: Fine Phase Execute 1: Fine Phase Not Execute
0 - 1 1
4 BLKDET Black Level Detect Area 0 - 7 1
5 PHASEMSK
Phase Detect Filter
0: All Bits Enable, 1: Lower 1 bit Disable, 2: Lower 2 bit Disable, 3:
Lower 3 bits Disable
0 - 3 0
290 Panel Type (Not Effective)