-48-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group 250 FAN Control * Fan control adj.
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan Volage.
* Lamp mode is forced Eco
10 0 - 255
1 FAN1 MAX ADJUST (DAC) 225 0 - 255
2 FAN2 MIN ADJUST (DAC) 26 0 - 255
3 FAN2 MAX ADJUST (DAC) 225 0 - 255
4 FAN3 MIN ADJUST (DAC) 10 0 - 255
5 FAN3 MAX ADJUST (DAC) 225 0 - 255
6 Not used
7 Not used
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH 0: Normal, 1: Hi-Land, 2-4: Hi-Land 1-3 0 0 - 5
1 SAFETY SWITCH For test purpose 0 0 - 6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual switch is 1
100 0 - 255
4 FAN2 MANUAL VOLTAGE 100 0 - 255
5 FAN3 MANUAL VOLTAGE 100 0 - 255
6 Not used
7 Standard Mode Mode Setting 0 0-4
8
Fan Offset Voltage Update
Interval
Fan Voltage Update Intervval while
clogging(Unit:Second)
60 1-600
Group 253 Fan Tem Error Setting (Memorized)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
43 43 33 33 30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at Normal
(Panel)
65 65 56 55 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at Normal
(Lamp)
72 72 64 63 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco) Temp. A to judge the Temp Error at Eco (Room) 42 42 38 36 30-100
11 Temp B Warning (Eco) Temp. B to judge the Temp Error at Eco (Panel) 62 62 56 55 30-100
12 Temp C Warning (Eco) Temp. C to judge the Temp Error at Eco (Lamp) 67 66 62 61 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
5 0-100
17
Temp C Warning Offset
(Temp)
5 0-100
18
Temp B-A Warning Offset
(Temp)
0 0-100
19
Temp C-A Warning Offset
(Temp)
0 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-20
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
25 Factory Mode For factor use 0 0-1
Group 254 Fan Control Range Setting (Temp./Voltage)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Not used 9999 9999
1 Not used 9999 9999
2 Not used 9999 9999