-49-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
3 Not used 9999 9999
4 Not used 9999 9999
5 Not used 9999 9999
6 Not used 9999 9999
7 Not used 9999 9999
8 Not used 9999 9999
9 Not used 9999 9999
10
Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.p at Nor-
mal
28 28 20 20 20-100
11
Normal Fan Control Max
Temp
37 37 20 20 20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
75 80 120 125 0-255
13 Normal Fan1 Max 135 135 120 125 0-255
14 Normal Fan2 Min 75 80 125 125 0-255
15 Normal Fan2 Max 100 105 125 125 0-255
16 Normal Fan3 Min 70 70 110 115 0-255
17 Normal Fan3 Max 80 90 110 115 0-255
18 Normal Fan4 Min 9999 9999 -
19 Normal Fan4 Max 9999 9999 -
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
28 28 20 20 20-100
21 Eco Fan Control Max Temp 38 38 20 20 20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
60 65 100 105 0-255
23 Eco Fan1 Max 80 85 100 105 0-255
24 Eco Fan2 Min 55 65 110 115 0-255
25 Eco Fan2 Max 90 100 110 115 0-255
26 Eco Fan3 Min 55 50 70 70 0-255
27 Eco Fan3 Max 60 60 70 70 0-255
28 Eco Fan4 Min 9999 9999 -
29 Eco Fan4 Max 9999 9999 -
30 Filter Error Detect Temp Detected Temp for Filter Blocked (Temp B-A) 18 18 50 50 0-100
31 Filter Error Offset Vot Offset Volt for Filter Blocked (Unit: 0.1V) 3 3 10 10 0-255
Group 255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
55 0-255
1 Fan2 Initial Volt 55 0-255
2 Fan3 Initial Volt 55 0-255
3 Not used 255(Dummy) -
4 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 130 0-255
5 Fan2 Cooling Speed 130 0-255
6 Fan3
Cooling Speed 80 0-255
7 Not used 255(Dummy) -
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
2 1-15
9 Cooling Time L2
Cooling Time stting at Fan Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x 30 sec) 1:
30, 3: 90, 15: 450 sec.
3 1-15
11
OnStart Cooling Start Thresh-
old
38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (0.1V)(Read only) - 0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage Down ( V×
10)
0 30-90
2 Fan1 Speed Gain
Additional Fan Speed of Min at Lamp Voltage
Down (unit: 0.1V)
10 0-255
3 Fan2 Speed Gain 10 0-255
4 Fan3 Speed Gain 10 0-255
5 Not used 9999(Dummy) 0-255
Group 257 Fan Dimmer Setting
0
Dimmer Average Check
Period
Dimmer Average measurement Time
(0:10sec, 1:30sec, 2:60sec,
90sec...10:300sec)
1 0-10
1 Dimmer Average Dimmer Average Value (Read only) -
2 Last Voltage Difference -
3 Voltate Difference Goal
Group 258 Fan IC Temp for Netowrk model
0 Not used
1 Not used