EasyManua.ls Logo

Sanyo PLC-XC56 - Configurations of Terminals

Sanyo PLC-XC56
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
Appendix
COMPUTER IN 1 /COMPONENT IN /MONITOR OUT (ANALOG)
Terminal: Analog RGB (Mini D-sub 15 pin)
5
1
2
34
10
9 678
15
14 13
11
12
Red (R/Cr) Input/Output
Ground (Horiz.sync.)
Green (G/Y) Input/Output
-----
Blue (B/Cb) Input/Output
Ground (Red)
Ground (Green)
Ground (Blue)
1
5
2
4
3
6
7
8
+5V Power/-----
Horiz. sync. Input/Output (Composite H/V sync.)
Ground (Vert.sync.)
DDC Data
/-----
Ground/-----
Vert. sync.
DDC Clock
/-----
9
13
10
12
11
14
15
RX –
TX +
TX –
RX +
2
3
4
87654321
5
6
7
8
1
LAN TERMINAL
-----
-----
----------
COMPUTER 2 / DVI-I TERMINAL (DIGITAL/ANALOG)
1
9
17
2
10
18
3
11
19
4
12
20
5
13
21
6
14
22
7
15
23
8
16
24
C1
C2
C3
C5
C4
T.M.D.S. Data2–
No Connect
T.M.D.S. Data2+
No Connect
T.M.D.S. Data2 Shield
DDC Clock
DDC Data
Analog Vert. sync
1
5
2
4
3
6
7
8
T.M.D.S. Data1–
No Connect
T.M.D.S. Data1+
No Connect
T.M.D.S. Data1 Shield
+5V Power
Ground (for +5V)
Hot Plug Detect
9
13
10
12
11
14
15
16
T.M.D.S. Data0–
No Connect
T.M.D.S. Data0+
No Connect
T.M.D.S. Data0 Shield
T.M.D.S. Clock Shield
T.M.D.S. Clock+
T.M.D.S. Clock–
17
21
18
20
19
22
23
24
Analog Red Input
Analog Ground (R/G/B)
Analog Green Input
Analog Horiz. sync
Analog Blue Input
C1
C5
C2
C4
C3
CONTROL PORT CONNECTOR (D-sub 9 pin)
-----
R X D
T X D
2
3
4
1
-----
-----
5
6
7
8
SG
RTS
CTS
Serial
-----9