Electrical Adjustment
Grp Item Item Name Function Range Initial
143 Fan Manual Control
0 Fan Fix SW
0:normal / 1:Normal Min / 2:Normal Max / 3:Eco Min / 4 :Eco Max
* Not memorized , Abnormal temp=100°C
0 ~ 4 0
1 Fan Manual SW FanManual Control SW 0:Auto / 1:Manual * Not memorized 0 / 1 0
2 Fan A Manual Out
Fan Voltage at Manual Mode * Not memorized (x0.01V)
* Effective only Fan Manual SW is 1
0 ~ 2000 1350
3 Fan B Manual Out 0 ~ 2000 1350
4 Fan C Manual Out 0 ~ 2000 1350
5 Fan D Manual Out 0 ~ 2000 1350
6 Fan E Manual Out 0 ~ 2000 1350
7 Fan F Manual Out 0 ~ 2000 1350
144 Fan Table Setting
0 Fan Control Max Temp Fan control range of Temp Sensor A (x0.01V) 300 ~ 1000 380
1 Fan Control Min Temp 0 ~ 1000 310
2 Fan A Normal Max (Volt) Fan control range at Lamp Normal (x0.01V) 0 ~ 2000 1350
3 Fan A Normal Min (Volt) * It does not change with real time 0 ~ 2000 900
4 Fan B Normal Max (Volt) 0 ~ 2000 1350
5 Fan B Normal Min (Volt) 0 ~ 2000 700
6 Fan C Normal Max (Volt) 0 ~ 2000 1380
7 Fan C Normal Min (Volt) 0 ~ 2000 1380
8 Fan D Normal Max (Volt) 0 ~ 2000 1350
9 Fan D Normal Min (Volt) 0 ~ 2000 1200
10 Fan E Normal Max (Volt) 0 ~ 2000 1350
11 Fan E Normal Min (Volt) 0 ~ 2000 700
12 Fan F Normal Max (Volt) 0 ~ 2000 1350
13 Fan F Normal Min (Volt) 0 ~ 2000 700
14 Fan A Eco Max (Volt) Fan control range at Eco Normal (x0.01V) 0 ~ 2000 1350
15 Fan A Eco Min (Volt) * It does not change in real time 0 ~ 2000 500
16 Fan B Eco Max (Volt) 0 ~ 2000 1350
17 Fan B Eco Min (Volt) 0 ~ 2000 500
18 Fan C Eco Max (Volt) 0 ~ 2000 700
19 Fan C Eco Min (Volt) 0 ~ 2000 700
20 Fan D Eco Max (Volt) 0 ~ 2000 1350
21 Fan D Eco Min (Volt) 0 ~ 2000 1100
22 Fan E Eco Max (Volt) 0 ~ 2000 1350
23 Fan E Eco Min (Volt) 0 ~ 2000 500
24 Fan F Eco Max (Volt) 0 ~ 2000 1350
25 Fan F Eco Min (Volt) 0 ~ 2000 500
145 Fan Temp. Offset Setting
0 Temp A Warning Offset (Temp) Temp. warning offset value at Power On (x0.1℃ ) 0 ~ 200 170
1 Temp B Warning Offset (Temp) 0 ~ 200 170
2 Temp C Warning Offset (Temp) 0 ~ 200 170
3 Temp B-A Warning Offset (Temp) 0 ~ 200 170
4 Temp C-A Warning Offset (Temp) 0 ~ 200 170
5 Temp A Warning Offset (Time) Temp. warning offset time at Power On (sec.) 0 ~ 300 180
146 Fan Start Setting
0 Fan Start Step (Volt/Sec) Voltage deviation/1 sec at Fan start (Volt/Sec) 0 ~ 2000 20
1 Fan A Start Volt Fan start voltage (x0.01V) 0 ~ 2000 700
2 Fan B Start Volt 0 ~ 2000 700
3 Fan C Start Volt 0 ~ 2000 700
4 Fan D Start Volt 0 ~ 2000 700
5 Fan E Start Volt 0 ~ 2000 700
6 Fan F Start Volt 0 ~ 2000 700
147 Fan Pressure Setting
0 Press Source Range Low Press sensor control range (mmHG) 0~1024 525
1 Press Source Range High 0~1024 700
2 Press Fan Add Range High 0 ~ 2000 0
3 Press Fan Add Range Low 0 ~ 2000 650
148 Fan Ceiling Setting
0 FAN A Ceiling Offset Offset voltage at Ceiling (x0.01V) 0 ~ 2000 0
1 FAN B Ceiling Offset 0 ~ 2000 0
2 FAN C Ceiling Offset 0 ~ 2000 0
3 FAN D Ceiling Offset 0 ~ 2000 0
4 FAN E Ceiling Offset 0 ~ 2000 0
4 FAN F Ceiling Offset 0 ~ 2000 0