Electrical Adjustment
Grp Item Item Name Function Range Initial
149 Fan Clogged Setting
0 Temp C-A Upward High Fan voltage addition by Sensor A - C temp Upward High 0 ~ 1000 300
1 Temp C-A Upward Low Fan voltage addition by Sensor A - C temp Upward Low 0 ~ 1000 280
2 Temp C-A Downward High Fan voltage addition by Sensor A - C temp Downward High 0 ~ 1000 150
3 Temp C-A Downward Low Fan voltage addition by Sensor A - C temp Downward Low 0 ~ 1000 110
150 Shipping Setting
0 Shipping Setting Shipping Set when the value is set to 10. 0 ~ 10 0
170 Wind Sensor
0 Flow Sensor Calibration
Wind Sensor Offset Auto-Calibration
Calibration starts when the value is set to 1. After calibration, OK is displayed.
0 ~ 1 0
1 Flow Sensor Offset Min
Wind Sensor Mini Offset value
* After calibration, the value is set automatically.
(Offset Range: 350 - 550)
0 ~ 1023 0
2 Flow Sensor Offset Max
Wind Sensor Max Offset value
* After calibration, the value is set automatically.
(Offset Range: 550 - 800)
0 ~ 1023 0
3 Flow Sensor Calibration Error Log
Error Log for Auto-Calibration
0: No Error
10: Min not stabilized
11: Min out of offset range
20: Max not stabilized
21: Max out of offset range
4 Clog Check Enable Clogged Detection (0: Disable / 1: Enable) 0 ~ 1 Initial= 0, Ship=1
171 Wind Sensor
0 Ideal Flow Data Airow data theory for current fan voltage (Read only) - -
1 Flow Difference Data Differential value between actual and theory (Read only - -
2 Clog Detect Flow Difference Data Differential value to judge “Clogged(Read only) - -
3 Warn Detect Flow Difference Data
Differential value to judge “Clogged warning" (Read only)
Judge when the remaining scroll times is 0.
- -
4 Press Add Data Additional value of press sensor - -
5 Filter Scroll Timer
Filter scroll timer (hours)(Read only)
* Execute at 2000 hours
- -
175 Filter
0 Compulsion Filter Taking Up
Filter scroll forcedly
*Execute when the value is set to 1
0 ~ 1 0
1 Take Up Bend
Remove flexure of filter
*Execute when the value is set to 1
0 ~ 1 0
2 Take Up Times Filter scroll remaining times (Read only) - 9
3 Take Up Time Reset
Reset of scroll up times
*Reset when the value is set to 10.
0 ~ 10 0
4 Scroll Counter Reset Time Scroll Counter reset times (Read only) 0 ~ 255 0
176 Filter Dispplay
0 Filter Icon Display Display 0: Disable / 1: Enable 0/1 1
177 Filter Timer
0 Filter Timer Reset Times Filter time reset times with user menu 0 ~ 255 0
1 Force Power Off Time Forced Power Off Time (hours) 0 ~ 1000 10
180 DDC Setting
0 HDCP EDID Data Setting 0:DVI EDID Data / :HDCP EDID Data 0 / 1 1
190 Panel Life Test
0 Panel Life enable 0: Test Mode ON, Test Mode OFF 0 / 1 1
200 CXA7007
0 G SIG Center 0 ~ 63 32
1 B SIG Center 0 ~ 63 32
2 R SIG Center 0 ~ 63 32
3 G Gain Control 0 ~ 255 194
4 B Gain Control 0 ~ 255 194
5 R Gain Control 0 ~ 255 194
6 G Bright Control 0 ~ 255 0
7 B Bright Control 0 ~ 255 0
8 R Bright Control 0 ~ 255 0
9 G VCOM Control 0 ~ 255 104
10 B VCOM Control 0 ~ 255 104
11 R VCOM Control 0 ~ 255 104