7. EXPLANATION OF PARAMETERS
740
Mode Page
Abbre-
viation
Name and description
Standard
value
Unit
Setting
range
Remarks
1 9 VCI2 Internal velocity command value 2
Set a velocity command value.
It is enabled by setting the Func3 parameter
bits 3, 2, 1 and 0 to "1010", and turning the
CN1-35 pin on and the 36 pin off.
1000 min
-1
0 to
32767
Velocity control
10 VCI3 Internal velocity command value 3
Sets a velocity command value.
It is enabled by setting the Func3 parameter
bits 3, 2, 1 and 0 to "1010", and
simultaneously turning both the CN1-35 pin
and the 36 pin on.
1500 min
-1
0 to
32767
Velocity control
11 IILM Internal current limit value
You can clamp the current at the value set
from this page by setting the Func1
parameter bit0 to 0, and entering ILM
(CN1-31 pin).
Setting of a value greater than IP is not
available.
This setting is available within the range of
IP/IR × 100.
IP : Momentary maximum stall current on
the armature.
IR : Rated armature current.
100 % 30 to
(IP/IR)
× 100

Table of Contents