7. EXPLANATION OF PARAMETERS
7-41
Mode Page
Abbre-
viation
Name and description
Standard
value
Unit
Setting
range
Remarks
1 12 SILM Sequence current limit value
• Sets a current limit value for holding brake
sequencing, overtravel or JOG operation.
• This setting is available within the range of
IP/IR × 100.
120 % 30 to
(IP/IR)
× 100
13 THB Holding brake excitation timing
• Sets the holding brake excitation timing.
• Select "0" when this function is not used.
300 mSec 0 to
1000
Timing setting
is available in
multiples of
4 msec.
14 VCMS Velocity command scale
• Sets a velocity command scale corresponding
to 1 V of the command voltage.
500 min
-1
/
V
0 to
3000
15 TCMS Torque command scale
• Sets a torque command scale corresponding
to 1 V of the command voltage.
50 %/V 0 to
400

Table of Contents