EasyManua.ls Logo

Sanyo SUPER BL PY - Page 136

Sanyo SUPER BL PY
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. EXPLANATION OF PARAMETERS
741
Mode Page
Abbre-
viation
Name and description
Standard
value
Unit
Setting
range
Remarks
1 12 SILM Sequence current limit value
Sets a current limit value for holding brake
sequencing, overtravel or JOG operation.
This setting is available within the range of
IP/IR × 100.
120 % 30 to
(IP/IR)
× 100
13 THB Holding brake excitation timing
Sets the holding brake excitation timing.
Select "0" when this function is not used.
300 mSec 0 to
1000
Timing setting
is available in
multiples of
4 msec.
14 VCMS Velocity command scale
Sets a velocity command scale corresponding
to 1 V of the command voltage.
500 min
-1
/
V
0 to
3000
15 TCMS Torque command scale
Sets a torque command scale corresponding
to 1 V of the command voltage.
50 %/V 0 to
400

Table of Contents

Related product manuals