Settings
20
appl
appl 1
1
)
Znm / neutr.m Neutral measurement
3.5. Minimum load for automatic taring and automatic printing
2
)
Numeric menu similar to Counting
3.6. Minimum load for initialization
Numeric menu similar to Counting
3.7. Automatic taring: first weight tared
2
)
Numeric menu similar to Counting
3.8.
Automatic start of applications when you switch on the device with most recently saved application data
2
)
Numeric menu similar to Counting
3.9. Reference value calculation resolution
3.9.1 * Display accuracy
3.9.2 Display accuracy + 1 decimal place
3.9.3 Display accuracy + 2 decimal places
3.9.4 Internal resolution
3.10. Decimal places in displayed result
3.10.1 * none
3.10.2 1 decimal place
3.10.3 2 decimal places
3.10.4 3 decimal places
3.11. Parameter for saving weight values
3.11.1 * With stability
3.11.2 With increased stability
3.13. Reference weighing instrument
3.13.1 * No weighing platform selected
3.13.2 To weighing platform WP 1
3.13.3 To weighing platform WP 2
3.25. Tare function
2
)
Numeric menu similar to Counting
9.1. Factory settings for all application programs
2
)
9.1.1 Yes
9.1.2 No
V / anim.wg Averaging (animal weighing)
3.5. Minimum load for automatic taring and automatic printing
2
)
Numeric menu similar to Counting
3.6. Minimum load threshold for automatic start
Numeric menu similar to Counting
3.7. Automatic taring: first weight tared
2
)
Numeric menu similar to Counting
3.8
Automatic start of applications when you switch on the device with most recently saved application data
2
)
Numeric menu similar to Counting
3.18. Start of averaging
3.18.1 * Manual
3.18.2 Automatic
3.19. Animal activity
3.19.1 0.1% of the animal/object
3.19.2 * 0.2% of the animal/object
3.19.3 0.5% of the animal/object
3.19.4 1% of the animal/object
3.19.5 2% of the animal/object
3.19.6 5% of the animal/object
3.19.7 10% of the animal/object
3.19.8 20% of the animal/object
3.19.9 50% of the animal/object
3.19.10 100% of the animal/object
3.20. Results printout
3.20.1 * Manual
3.20.2 Automatic
3.21. Static display of result after load removed
3.21.1 * Display is fixed until unload threshold reached
3.21.2 Fixed display until c is pressed
3.25. Tare function
2
)
3.25.1 * Can add a preset tare if tare value is available; however no tare function possible
3.25.2 When a preset tare is entered, the tare value is deleted; however tare function activation is possible
9.1. Factory settings for all application programs
2
)
9.1.1 Yes
9.1.2 * No
2
) For Signum
®
2 only