Totalizing Application s
73
 Preparation
§ Switch on the scale: Press the e key
§ While all segments are lit, press the 
) key
§ Select the Setup menu: Press the 
k key repeatedly until appl is 
displayed
§ Confirm appl: Press the ) key
§ Select the Totalizing application:
  Press the k key repeatedly and 
confirm with the ) key
  Totalizing Application Parameters
    3. 6.   Minimum load for autosave
      3.6.1*  1 digit
      3.6.2  2 digits
      3.6.3  5 digits
      3.6.4  10 digits
      3.6.5  20 digits
      3.6.6  50 digits
      3.6.7  100 digits 
    3.6.8  200 digits
      3.6.9  500 digits
      3.6.10  1000 digits
    3.16.   Autosave mode
      3.16.1*  Off
      3.16.2  On
 
  3.17.    Individual/Component printout 
when saved
      3.17.1   Automatic printing off
      3.17.2*   Print the entire standard 
print configuration 
every time with the O 
key
   
    3.22.   Source of data for autosave
      3.22.1*  Application 1
      3.22.2  Application 2
    3.23.  Saved value
      3.23.1*  Net
      3.23.2  Calculated
      3.23.3  Net and Calculated
  * = Factory setting
§ Save the settings with the ) key and 
exit Setup: Press the ( key several 
times.
  Minimum load 
  The minimum load required for 
automatic taring of the container 
weight on the platform (first weight) 
is configured in Setup under:
Appl: 
s: 3.5.
Signum
®
 3:
  Appl: m.weigh: 3.5. 
  The minimum amount that a 
component must weigh before it 
can be saved in totalizing memory 
is configured in Setup under:
Appl: 
s: 3.6.
Signum
®
 3:
  appl 3
:  
totaliz: 3.6.
  You can choose from the following 
10 levels for this setting:
  1 digit
  2 digits
  5 digits
  10 digits
  20 digits
  50 digits
  100 digits
  200 digits
  500 digits
  1000 digits
  The “digits” here refer to the scale 
intervals in the connected weighing 
platform. If the interval of the 
connected platform is 1 g, for example, 
and 1000 digits are required, you must 
place at least 1000 g (=   1000 intervals 
= 1000 digits) on the weighing platform 
for autotaring (only with the “Autotare 
first weight” option selected).
 Protocol
  In Setup, under: 
Appl: 
s: 3.17.
Signum
®
 3:
  appl 3: 
totaliz: 3.17.
  You can configure whether a printout 
is generated manually, by pressing p, 
or automatically when a weight value is 
stored in the totalizing memory. 
  If you select the 3.17.1 menu item, 
printouts can only be generated 
manually by pressing the p key 
(single printout).
  If the 3.17.2. menu item is selected 
(Print one component), the component 
record is printed.
  The total data record is printed when 
you clear the totalizing memory 
(by pressing the c key).