Unit 4: Standard Command Codes
SATO GL4xxe SBPL Programming Reference Page 4-47
DATA MATRIX CODE, SEQUENTIAL NUMBER
FUNCTION
Specifies sequential numbering for the data matrix code of 2D code.
FORMAT
<ESC>FX
a = Quantity of duplications to print (001 to 999)
b = Flag of increase/decrease
+: Increase
-: Decrease
c = Quantity of increase/decrease (001 to 999)
d = Specification of digit position (001 to 999)
e = Digit number (001 to 999)
Place before <ESC>BX.
EXAMPLE
<ESC>A
<ESC>H0100<ESC>V0100<ESC>FX001+001005003
<ESC>BX011002020000000001
<ESC>DC00006000
<ESC>Q1
<ESC>z
OUTPUT
Label Set 1:
(4-34a)
Label Set 2:
(4-34b)
NOTES
This code must be placed before the <ESC>BX command.