44
SBS-6500 User Manual
Storage Battery Systems, LLC.
7.7. Review of Recorded Data
Recall any recoded data from memory and replay the data.
[Operation Procedure]
① Press key to enter data display screen.
② Press key to select “Record” then press to enter.
③ Select the string you want to review the data in.
④ Select the data from recorded data address by direction key or
ENCODER key. Then press key to view the recorded data on display.
⑤ When in replay mode, the record data with record number is displayed on the LCD
screen.
⑥ To view data of another table entry, press which will take you back to
the table and you can select another data block.
⑦ Press to exit from the replay function.
[NOTE]
Selected memory block data is displayed at the bottom of the screen without going
into replay.
Condition of the cell/battery is displayed by the symbol in the data block table
(P,W,F,G ). A blank box indicates no data is stored in that location.
[Replay LCD screen]
Upper center of screen shows Replay.
Record number of replay data shows at upper left of screen.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com