35
SCClub operating instructions
Operation
4.15 Drip tray
Danger of scalding
• Hot liquids could be in the drip tray.
> Carefully move the drip tray.
> Reinstall it carefully so that no unintended
water leakage occurs.
In co ee machines without an outlet connection, the
lling level sensor reports when the drip tray is full.
* Carefully remove the drip pan, empty it and
reinstall it.
The drip pan can also be removed, for
cleaning for instance, in co ee machines with
a drain connection.
Drip tray sensor
A sensor monitors whether the drip tray is inserted
and what the ll level is. A noti cation appears on the
display if the ll level is at the maximum amount.
* After receiving a noti cation, carefully remove the
drip pan, empty it and reinstall it.
The underside of the drip tray and the area
of the drip tray sensor must be dry before
insertion. The sensor is located on the right
under the drip tray. If moisture remains in this
area, the “Empty drip tray” message appears
again.
CAUTION
Observe the Safety chapter
w from page 9
Clean the drip tray daily
Care w from page 70
NOTE
IMPORTANT
This sticker marks the area
which should be kept dry.