99
SCClub operating instructions
Notications and notes
Error
number
Error
description
Instruction
163 Water error:
Warm rinsing
Switch the coee machine o and on again after every one of the
following steps. If the error is not xed, perform the next step.
* Clean the brewing unit
w Care w Brewing unit cleaning, page 82
* If the error is not xed, call Schaerer Service
186 Steam boiler:
level
Dispensing is temporarily disabled.
* Check that the grounds container has been
installed correctly
* Switch the coee machine o and back on
188 Heating error;
Steam boiler
overtemperature
* Switch o the additional coee machine, pull
out the mains plug
* Call Schaerer Service
189 Steam boiler:
heating time error
* Switch the coee machine o and back on
* If the error is not xed, call Schaerer Service
w Care w Cleaning the milk system by hand, page 85
9083 Cooler
temperature is in
the frost range
* Check whether the cooler temperature is set
too low
9516
9517
Right grinder
blocked
Left grinder
blocked
* Switching o the coee machine
* Pull the power plug
* Remove bean hopper lids
* Empty the bean hopper
* Turn the grinding disk anticlockwise only using
the multi-tool for the container (two pins must
be inserted into the respective recesses of the
grinder, see gure)
* Fill the bean hoppers
* Put the bean hopper lids back on
* Switching on the coee machine
w Care w Bean hopper cleaning, page 89
If this happens frequently:
* Set the grinding neness one level coarser
w Other settings w Setting grind level, page 69