Service and maintenance www.schaerer.com
Prompt occurs only with an internal
water filter (optional)
Prompt occurs only with an internal
water filter (optional)
Display message, if with "mains wa-
ter supply" (optional)
3. 3-fold system rinsing
► Rinse the drinking water tank with water, fill it and reinsert it.
► Empty the collecting container and drip tray and place them back under the outlets.
► Continue the descaling process by pressing the field "Continue".
Rinsing starts and is then repeated with 2 additional identical rinsing procedures.
► Empty and replace the collecting container and drip tray after the 3rd system rinse.
► Fill and insert the drinking water tank.
► Continue the descaling process by pressing the [Continue] field.
4. Preparing for operation.
► Follow the optional display instruction for machines with an internal water filter. See option
"With water filter".
► Continue the descaling process by pressing the "Continue" field.
There is a danger of scalding in the dispensing area.
The machine heats up automatically, so do not reach under the dispensing areas.
► Confirm the display message "Caution! Heating up!" by pressing the "Continue" field.
The machine heats up automatically.
The display message "Descaling completed correctly" appears.
► Confirm the display message by pressing the [Continue] field.
The machine heats up and starts "warm rinsing".
The machine blows steam out of the steam outlet.
► Switch over again, if the machine has an optional mains water supply. See below "Option:
With mains water supply"
The descaling process is complete and the machine is ready for operation.
Option 1: With water filter
If an optional internal water filter is used in the drinking water tank, the "Remove calcium filter
from tank" display instruction appears after the cooling down routine.
► Remove the water filter (optional) from the drinking water tank before pouring in the des-
caler.
► Then continue the descaling process by pressing the [Continue] button.
► Follow the ensuing display instructions, see descaling process.
► Reinsert the water filter at the end of the descaling process.
See "Service and maintenance" - "Water filter (optional)" - "Changing the water filter for the
internal drinking water tank".
Option 2: With mains water supply
If a mains water supply connection is available, the "Change Aquaflex" display instruction ap-
pears after the descaling process starts.
► Close the main water valve of the mains water supply.
► Remove the right-hand front cover.
► Switch from the mains water supply to "drinking water tank".
See "Installation and commissioning" - "Switching between mains water supply and drinking
water tank"
BA SCV_EN
V06 | 11.2015
61