Assembly
05.00 | AGE-XY | Assembly and operating manual | en | 389007 17
"Locked"
compensation unit
1. Apply pressure to connection B to lock the AGE.
2. Push magnetic switch 1 into the profile groove until it
switches.
3. Mount magnetic switch 1 in this position with the screw in
the magnetic switch.
4. Unlock and lock the AGE to test its function.
"Unlock"
compensation unit
1. Apply pressure to connection A to unlock the AGE.
2. Push magnetic switch 2 into the profile groove until it
switches.
3. Mount magnetic switch 2 in this position with the screw in
the magnetic switch.
4. Unlock and lock the AGE to test its function.