EasyManuals Logo

SCHUNK DRG 44 User Manual

Default Icon
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Assembly
28 06.00 | DRG | Assembly and operation manual | en | 389041
5.4.2 DRG 100
1. Switch off the compressed air supply and leave the gripper
unpressurized in the "Closed" position.
2. Unscrew the locking screw (14).
3. Unscrew the adjustment screw (15) using a hexagon socket
wrench SW6 until the desired opening angle is reached.
4. Test the set opening angle by actuating the gripper with
compressed air. If necessary, switch off the compressed air
supply and repeat step 3.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK DRG 44 and is the answer not in the manual?

SCHUNK DRG 44 Specifications

General IconGeneral
BrandSCHUNK
ModelDRG 44
CategoryTools
LanguageEnglish

Related product manuals