Assembly
28 06.00 | DRG | Assembly and operation manual | en | 389041
5.4.2 DRG 100
1. Switch off the compressed air supply and leave the gripper
unpressurized in the "Closed" position.
2. Unscrew the locking screw (14).
3. Unscrew the adjustment screw (15) using a hexagon socket
wrench SW6 until the desired opening angle is reached.
4. Test the set opening angle by actuating the gripper with
compressed air. If necessary, switch off the compressed air
supply and repeat step 3.