Technical data
18
11.00 | EGP | Assembly and Operating Manual | en | 389476
3.1.2 EGP 40
Designation EGP
40 40-S
Supply voltage [VDC]
Min. [VDC]
Max. [VDC]
24
21.6
26.4
Min. Supply current power
supply unit [A] *
1.0
Max. Current input [A]** 2.0
Gripping force [%] 25 50 75 100 100
Current input in blocked
state [A] ***
0.05 0.10 0.15 0.20 0.20
Integrated electronic control unit
Communication interface Digital I/O
Number of digital inputs/
outputs 2/2
Designation EGP 40 IO-Link
Supply voltage [VDC]
Min. [VDC]
Max. [VDC]
24
21.6
26.4
Min. Supply current power
supply unit [A] *
1.0
Max. Current input [A]** 2.0
Gripping force [%] 25 50 75 100
Current input in blocked
state [A] ***
0.05 0.10 0.15 0.2
End position detection
tolerances [mm]
(in delivery status / after
stroke measurement) ±0.5
Integrated electronic control unit
Communication interface IO-Link
Specification: V1.1
Transmission rate COM2
Port Class B
* minimum supply current for reliable operation of product
**
maximum current input in the acceleration phase (max. t = 50 ms)
*** Current input in blocked state (in gripper end position or
while gripping a workpiece) with active command "Open
Gripper" or "Close Gripper"
More technical data is included in the catalog data sheet.
Whichever is the latest version.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCHUNK EGP Series and is the answer not in the manual?

SCHUNK EGP Series Specifications

General IconGeneral
BrandSCHUNK
ModelEGP Series
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals