Assembly
24 14.00 | GSM-P | Assembly and Operating Manual | en | 389104
Mounting the unit
Mounting the unit on the base side
(with adapter plate similar to A, B or C; see "Mounting the GSM at
the side and on the base side")
The assembly of the unit can be carried out from the side of the
unit using the screws (6).
There are threads in the housings for mounting from the
customer-specific opposite side (screws 5 and 6 are not included
in the scope of delivery).
Use the centering sleeves (2) for the secure transmission of lateral
forces and the positioning of the unit.
Mounting the unit at the side
(with adapter plate similar to A, B or C)
The assembly of the unit can be carried out from the side of the
unit using the A2 screws included in the accessory kit (3A, 3B or
3C).
There are threads in the housings for mounting from the
customer-specific opposite side. (The A2 screws (4A, 4B or 4C) are
included in the accessory kit.)
Use the centering sleeves (1A, 1B or 1C) for the secure transmission
of lateral forces and positioning of the unit.
NOTE
In order to guarantee process reliability for monitoring with
magnetic switches, the adapter plate and the attachments
located near the unit in particular should be made of non-
ferromagnetic material. Otherwise, monitoring with magnetic
sensors could be impaired considerably.
NOTE
When monitoring with magnetic switches, the minimum
distance between the units must be 10mm if multiple units are
installed next to each other.