Assembly
11.00 | PGN | Assembly and Operating Manual | en | 389286
23
4.2.2 Inductive proximity switch IN 80
Assembly and
adjustment of
proximity switch PGN
64, 80, 100, 125 and
160
NOTE
Interrogation of the proximity switch for PGN 50 is done without
control cams.
Gripper open:
Ø Set the gripper onto ”open“ position.
Ø Carefully push the closer into the bushing until the proximity
switch contacts the control cam.
Ø Draw back the proximity switch by appr. 0.5 mm.
Ø Fasten the proximity switch with the set-screw (23).
In case of PGN 64 fasten the clamping screw at the bracket.
Ø Connect the proximity switch.
Ø Control the function by opening and closing the gripper.
NOTICE
The max. thightening torque for fastening screws of proximity
switches is 100 Ncm.
Gripper closed:
Ø Set the gripper onto ”closed“ position.
Ø Carefully push the closer into the bushing until the proximity
switch contacts the control cam.
Ø Draw back the proximity switch by appr. 0.5 mm.
Ø Fasten the proximity switch with the set-screw (23).
In case of PGN 64 fasten the clamping screw at the bracket.
Ø Connect the proximity switch.
Ø Control the function by opening and closing the gripper.