Sea-Bird Electronics, Inc.
1808 136
th
Place NE
Bellevue, Washington 98005 USA
Tel: 425/643-9866
Fax:425/643-9954
SBE 19plusV2
SEACAT PROFILER
Conductivity, Temperature, and Pressure Recorder
with RS-232 Interface
Serial Number: 19P53231-6266
User Manual, Version 003

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sea-Bird Electronics SBE 19plusV2 and is the answer not in the manual?

Sea-Bird Electronics SBE 19plusV2 Specifications

General IconGeneral
BrandSea-Bird Electronics
ModelSBE 19plusV2
CategoryMeasuring Instruments
LanguageEnglish

Summary

Section 1: Introduction

About this Manual

Explains the purpose and organization of the user manual for the SBE 19plus V2 SEACAT Profiler.

How to Contact Sea-Bird

Provides contact information for Sea-Bird Electronics, including address, phone, fax, and email.

Quick Start

Outlines the initial steps for setting up and operating the SBE 19plus V2.

Unpacking SBE 19plus V2

Details the typical contents of an SBE 19plus V2 shipment.

Section 2: Description of SBE 19plus V2

System Description

Provides an overview of the SBE 19plus V2 SEACAT Profiler's capabilities and modes of operation.

Specifications

Lists the technical specifications for the SBE 19plus V2, including measurement ranges and accuracy.

Dimensions and End Cap Connectors

Illustrates the physical dimensions and details the pinouts of the SBE 19plus V2 connectors.

Batteries

Describes the types of batteries used, their capacity, and endurance for the SBE 19plus V2.

External Power

Explains how to power the SBE 19plus V2 using an external source and cable length considerations.

Data Storage

Details the SBE 19plus V2's data storage capacity and calculations for different configurations.

Magnetic Reed Switch

Explains the function of the magnetic switch for starting/stopping logging in Profiling mode.

Configuration Options and Plumbing

Describes how the SBE 19plus V2 can be configured with auxiliary sensors and plumbing arrangements.

Section 3: Power and Communications Test

Software Installation

Provides instructions for installing the Sea-Bird software required for CTD operation.

Test Setup

Details the steps for connecting the instrument and verifying communication.

Test

Explains how to use the SeatermV2 terminal program to test communications and instrument status.

Section 4: Deploying and Operating SBE 19plus V2

Sampling Modes

Describes the two primary sampling modes: Profiling and Moored.

Profiling Mode

Details how to start and stop logging in Profiling mode, including command examples.

Moored Mode

Explains how to start and stop logging in Moored mode, including command examples.

Pump Operation

Covers general pump operation and specific settings for Profiling and Moored modes.

Command Descriptions

Provides detailed descriptions and sample outputs for instrument commands.

Status Commands

Explains commands used to get and display instrument status and configuration data.

General Setup Commands

Details commands for setting date/time, baud rate, echo, battery type, and logging initialization.

Pressure and Voltage Sensor Setup Commands

Covers commands for configuring pressure sensor type and enabling external voltage channels.

RS-232 Sensor Setup Commands

Explains how to interface with SBE 38 temperature sensors and GTDs.

Output Format Setup Commands

Details commands for setting the output format of collected data (hexadecimal or decimal).

Logging Commands

Describes commands used to start, stop, and manage data logging in Profiling and Moored modes.

Data Upload Commands

Explains commands for uploading stored data from the instrument's memory.

Polled Sampling Commands

Lists commands that request a single sample and store data in buffer or FLASH memory.

Testing Commands

Describes commands used to measure sensor outputs for calibration and diagnostics.

Acquiring Real-Time Data with SEASAVE

Guides users on setting up and using SEASAVE for real-time data acquisition and display.

Recovery

Provides instructions for instrument recovery, physical handling, and data uploading.

Uploading Data

Details the process of uploading data from the instrument's memory using Seaterm232.

Processing Data Using SBE Data Processing

Explains how to convert and process raw data using SBE Data Processing software.

Editing Raw Data File

Provides a procedure for editing raw .hex data files using WordPad.

Section 5: Routine Maintenance and Calibration

Connector Mating and Maintenance

Covers cleaning, inspection, and proper mating of connectors and cables.

Plumbing Maintenance

Details the procedure for cleaning the air release valve to ensure proper pump function.

Replacing / Recharging Batteries

Provides step-by-step instructions for replacing alkaline, NiMH, and Ni-Cad batteries.

Conductivity Cell Maintenance

Outlines procedures for cleaning, storing, and handling the conductivity cell.

Pressure Sensor Maintenance

Describes maintenance procedures for strain-gauge and quartz pressure sensors.

Replacing Anti-Foulant Devices (SBE 16plus, SBE 19plus)

Details the procedure for replacing anti-foulant devices on the conductivity cell.

Sensor Calibration

Explains the process of sensor calibration and Sea-Bird's recommendations.

Section 6: Troubleshooting

Problem 1: Unable to Communicate

Lists common causes and solutions for communication issues with the instrument.

Problem 2: No Data Recorded

Addresses issues related to the instrument not recording data, often due to full memory.

Problem 3: Nonsense or Unreasonable Data

Provides solutions for data files containing incorrect or out-of-range values.

Glossary

Appendix I: Functional Description and Circuitry

Sensors

Describes the sensor elements used in the SBE 19plus V2.

Sensor Interface

Explains how temperature, conductivity, and pressure sensors are interfaced with the electronics.

Battery Wiring

Details the internal wiring configuration of the battery pack and power PCB.

Appendix II: Electronics Disassembly/Reassembly

Disassembly

Provides instructions for safely disassembling the instrument's electronics.

Reassembly

Details the steps for correctly reassembling the instrument's electronics.

Appendix III: Command Summary

Appendix IV: AF24173 Anti-Foulant Device

PRECAUTIONARY STATEMENTS

Outlines hazards to humans and domestic animals, and personal protective equipment.

STORAGE AND DISPOSAL

Provides guidelines for safe storage and disposal of the anti-foulant device.

Appendix V: Replacement Parts

Limited Liability Statement