EasyManua.ls Logo

Seaga Quick Break Combo QB2000 - Page 53

Seaga Quick Break Combo QB2000
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53QB2000 9.2022 vers 1.0
8. TEST VEND
Thisfunctionteststhemotorononespeciedselection.
1. Press Service Mode Button
2. Press 8 for Selection motor test menu
3. Use number keys to enter selection to test and wait
4. Repeat for any other selections
5. Press * to exit to previous menu
9. SELECTION: ALL
This function tests all motors in sequence automatically. To stop the test, press * to exit.
NOTE: All selections should be empty prior to performing this test.
1. Press Service Mode Button
2. Press 9 for Selection motor test menu
3. Press * to exit to previous menu
10. TEST MODES
This menu contains diagnostic tests and settings for the following systems:
Relays System Logs*
• Vigilant Vend Sensor • On Door
• Drop Bias Setting* • Manual Defrost
TEST RELAYS
1. Press Service Mode Button
2. Press 0 for Test Modes
3. Press 1 to test relays
4. Press 1 to test Relay1
5. Press 1 to toggle relay ON/OFF
6. Press 2 to test Relay2
7. Press 2 to toggle relay ON/OFF
8. Repeat steps 6 and 7 for remaining relays 3 thru 6
9. Press * twice to exit to previous menu
OPTICS
Note: Not used on this model
LOG
Note: Do not use unless requested by trained personnel
1. Press Service Mode Button
2. Press 0 for Test Modes
3. Press 3 for Log
4.Usenumberkeystoenterpassword(2314)toviewlog

Related product manuals