57QB2000 9.2022 vers 1.0
Motor [Number] Jam A motor jam has been detected. Check motor and spiral for
blockage.
Motor [Number] Errors One or more motor errors have
been detected.
Test vend selection motor and
review information on motor
open, short, home switch and
jam conditions.
Motor Under Voltage The detected motor voltage is not
high enough to run the selection
motors.
Test vend selection motor for
correct operation. Replace
motor. Replace VMC.
Temperature Sensor Errors
Error Message Description Possible Solutions
Refrig Sensor # Open A temperature sensor or
harness is considered to have
an open electrical connection.
Where # is the sensor number.
Check sensor and sensor
harness for open connections.
Check for sensor readings.
Replace sensor if necessary.
Refrig Sensor # Short A temperature sensor or
harness is considered to have
an electrical short. Where # is
the sensor number.
Check sensor and sensor
harness for shorted connections.
Replace if necessary.
Refrig Health Safety The cabinet temperature and
time limit settings have been
exceeded.
Check sensor readings and
sensor harness for shorted
connections. Check for sensor
readings. Replace sensor if
necessary.
Vend Sensor Errors
Error Message Description Possible Solutions
Optical Sensor Error Not Applicable NA
Coin Changer Errors
Error Message Description Possible Solutions
Coin Mech Comm VMC does not have
communication with the coin
changer.
Check MDB Harness to changer.
Check for power on changer.
See changer service manual.
Coin Mech Tube Sns The coin changer has reported a
tube sensor error.
See changer service manual.
Coin Mech Inlet The coin changer has reported
an acceptor blockage.
Check changer tubes. See
changer service manual.
Coin Mech Tube Jam The coin changer has reported a
tube payout error.
Check changer tubes. See
changer service manual.
Coin Mech ROM The coin changer has reported a
program memory error.
See changer service manual.