58QB2000 9.2022 vers 1.0
Coin Mech Excess Esc The coin changer has reported
that a large number of coin
escrow requests have occurred.
Check changer escrow lever
position.
Coin Mech Coin Jam The coin changer has reported
that a coin is jammed in the coin
path.
Check changer coin path. See
changer service manual.
Coin Mech Low Accept The VMC has seen a low
acceptance rate on coins.
Review inserted coins. See
changer service manual.
Coin Mech Accpt Disc The coin changer has reported
that the coin validation acceptor
is disconnected.
Re-connect the coin changer’s
acceptor. See changer service
manual.
Coin Mech Route Err The coin changer reported that
a coin did not follow the correct
path.
Check changer coin path. See
changer service manual.
Bill Validator Errors
Error Message Description Possible Solutions
Bill Val Comm VMC does not have
communication with the bill
validator.
Check MDB Harness to
validator. Check for power on
validator.
Bill Val Stack Full The bill validator has reported
that the stacker is full of bills.
Check bill stacker box for bills.
See validator service manual.
Bill Val Motor Err The bill validator reports that
a validator motor error has
occurred.
See validator service manual.
Bill Val Jam The bill validator reports a bill is
stuck in the bill path.
Check validator bill path for bills.
See validator service manual.
Bill Val Stack Open The bill validator is reporting a
bill box is open or not installed.
Check bill stacker box for
open lid. See validator service
manual.
Bill Val Sensor Err The bill validator reports a
sensor error.
See validator service manual.
Card Reader 1 and 2 Errors
Error Message Description Possible Solutions
Card RDR1 or 2 Comm VMC does not have communi-
cation with the card reader.
Check MDB Harness to card
reader. Check for power on card
reader.
Card RDR1 or 2 Err The card reader reports an error See card reader service manu-
al.