XT Controllers for NLV-CN Compressors
Page 82 / 83
Item Code No. Description
AIO/DIO
Connector for DIO
Not available at
Secop
3-pole RAST-2.5 connector
Connector for AIO
Not available at
Secop
6-pole RAST-2.5 connector
Mains
and relay
connector
Connector for mains 105N9563
2-pole RAST-5 connector
P
1
K
2
1a 1b 2a 2b
1c 2d
Connector for RL1
Coded connec-
tors are not avail-
able at Secop.
Connector with
coding can be or-
dered directly at
the manufacturer.
For example:
Lumberg, Tyco,
Stocko, and
Molex
(You will find a
selection of se-
ries in the table
below)
Please find the
coding in chap-
ter 2
Connection of
power outputs
All connections
can also be done
via Faston 6.3 ×
0.8 mm connec-
tors
2-pole RAST-5 connector
P
1
K
2
1a 1b 2a 2b
1c 2d
Connector for RL2
2-pole RAST-5 connector
P
1
K
2
1a 1b 2a 2b
1c 2d
Connector for RL3
2-pole RAST-5 connector
P
1
K
2 3
1a 1b 2a 2b 3a 3b
1c 2d 3a 3b
Connector for RL4 and 5
3-pole RAST-5 connector
P
1
K
2 3
1a 1b 2a 2b 3a 3b
1c 2d 3a 3b
Connector for RL6 and 7 3-pole RAST-5 connector
Connector for RL8
3-pole RAST-5 connector
1
K
P
2 3
1a 1b 2a 2b 3a 3b
1c 2d 3a 3b
Lab tool
Gateway
Not available
at Secop
Can be done with RS485 to USB converter
Take a RJ45 cable, cut it and then connect "blue"
to TDB(+), "blue/white" to TDA(-) and "brown and
shield" to GND.
RJ45 Ethernet patch cable
Not available
at Secop
Connection between NLV controller and gateway
with DSUB-9/RJ45 adaptor
Tool4Cool
®
LabEdition Free of charge
https://www.secop.com/solutions/application-
show/variable-speed-drive-software-tool4cool
Manufacturer Rast 2.5 Rast 5 (IDC) Crimp Screw terminals
Lumberg
3521 3623
Stocko
Eco-Tronic ECO-Domo NF ECO-Domo crimp WIECON 8105
Tyco
Duoplug 2.5 Mono-Shape Tab STD-Timer (crimp)
Molex
Appli-Mate RAST 2.5 Appli-Mate RAST 5 Rast 5 crimp
10.2.
Third Party Order