Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
92
ON
1 2 3 4 5 6 7 8
Address = 63
ON
1 2 3 4 5 6 7 8
Address = 62
ON
1 2 3 4 5 6 7 8
Address = 61
Dipswitch # 1 is used to flash out the firmware version of the Cutband Receiver. To verify the firmware version of the
Cutband Receiver, toggle dipswitch #1 OFF then back ON. The yellow LED will flash on and off, pause, and flash on
and off again. Count the flashes (4 digit #). These will be the firmware version of the Cutband Receiver.
Dipswitch # 2 has to be ON for the Cutband Receiver to decode the cutband signal. The system will not operate
properly if dipswitch # 2 is in the OFF position.