Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
Power Supply Connections for the Cutband Receiver
Up to 50 Cutband Receivers can be connected in daisy chain using the 12V 4 AMP Power Supply with a maximum of
10 Cutband Receivers per input on the power supply.
NOTE: Only 30 Cutband Receivers per XIU
The cutband power wire is 14/2 Stranded Plenum Shielded The power wire is a UL requirement. Failure to use
this wire removes UL Listing
When using the SCP Power Supply, verify the voltage setting is at 12V not 24V.
COMMON POWER OUTPUTS
FUSED POWER OUTPUTS
N
P
PD8
N P S
MAIN FUSE
L G N
3.5A 250V
AL600ULXB
AC
+BAT-
DC
+ DC -
BAT FAIL NC C NO NC C NO
AC FAIL
FNAME
24VDC OPEN
12VDC CLOSED
115VAC
Power
Mains
Non-Power
Limited
+
-
Battery 1
COMMON POWER OUTPUTS
FUSED POWER OUTPUTS
N
P
12VDC
12VDC
+
_
+
_
1
2
3
4
5
6
7
8
ON
Secure Care Products, Inc
12v DC ONLY!
REV
P03290012 REV1
12v DC ONLY!
+
_
+
_
CutBand Receiver
A03290942
· Risk of shock
· Dry location use only
· For indoor use only
Refer to manufacturer’s
documentation when
installing the power supply
Use only one
battery for the
12VDC application
Verify switch is set
for 12VDC before
applying power to
Power Supply
STOP
APPENDIX G 4 AMP POWER SUPPLY FOR CUTBANDS