English
23
• Plugandsocketconnectionsaccordingto
IEC62196
• The charging system is only intended for opera-
tioninTT,TNCandTNCSnetworks.Thecharging
systemmustnotbeoperatedinITnetworks.
• The charging system is not suitable for charging
vehicleswithbatterieswhichproducegas(such
aslead-acidbatteries).
• Thechargingsystemisintendedexclusivelyfor
stationary installation. The charging system is
suitable for outdoor installation.
• Only persons who have read the operating
instructions may operate and use the charging
system.
• The electrical installation, start-up, and main-
tenance of the charging system may only be
performedbyqualiedelectricianswhohave
been correspondingly authorised by the operator.
• Thequaliedelectriciansmusthavereadand
understood the device documentation and must
comply with its instructions.
Requirements regarding the qualication
ofelectricians
Knowledgeofandcompliancewiththevesafety
rulesforworkingwithelectricalinstallations:
1. Isolate.
2. Secureagainstreactivation.
3. Checkabsenceofvoltage.
1. SAFETY INFORMATION
Pleaseobservethefollowinginformationforsafe
set-upandoperationoftheWallbox.
1.1 Information for the operator and
users of the charging system
• Read the operating instructions before putting
the charging system into operation.
• Ensurethatallpersonsworkingonorusing
this charging system have read the operating
instructions.
• Makesuretofollowtheregulationsandinstruc-
tionsforsafeworking.
• Keep the device documentation in a safe place
where it is always accessible to charging system
users.
• Ensure that unauthorised persons cannot access
the charging system.
1.2 Intended use
The charging system is intended to be used in
the private and semi-public sector, e.g. on private
property,companyparkingareasormachineryand
equipmentyards.Donotusethechargingsystem
inplaceswherepotentiallyexplosiveorcombustible
substances(suchasgases,liquidsordusts)are
stored or present. The charging system is intended
exclusivelyforchargingelectricvehicles.
• Mode3chargingaccordingtoIEC61851-1
Designation TechnicalSpecications
Regulations EN61851-1;EN61439-7(AEVSC)
Chargingcapacitytype3 upto11kW
Nominal voltage 230V/400V/1/3AC
Nominal current upto16Aadjustablefrom6Ato16Ain2Aincrements
Nominal frequency 50 Hz
Connectionmethod Springclipmethod
Chargingconnection/chargingcoupler Type 2
Length of charging cable 7.5 m
Operation/statusinformation LEDFrontPanel
Protectionrating IP54
Mechanicalimpactprotection IK08
Residual current detection DC6mA(IEC62955)
Ambienttemperature -25°Cto+40°C
ExternalDesign Wallmounted|Stelemounted
Protectionclass I
Overvoltage category III
Pollutiondegree 3
Sizes (HxWxD)410mmx295mmx114mm
Weight approx.8.5kg
-25