Pleasenote:
NeverassigndoublebusIDs.
BusID S4/1 S4/2 S4/3 S4/4
1 OFF OFF OFF ON
2 OFF OFF ON OFF
3 OFF OFF ON ON
4 OFF ON OFF OFF
5 OFF ON OFF ON
6 OFF ON ON OFF
7 OFF ON ON ON
8 ON OFF OFF OFF
9 ON OFF OFF ON
10 ON OFF ON OFF
11 ON OFF ON ON
12 OFF ON OFF OFF
13 ON ON OFF ON
14 ON ON ON OFF
15 ON ON ON ON
4.4 Switch S5
SwitchesS5/1,S5/2andS5/3arenotneededon
anyofthefollowerWallboxes.Settheseswitches
to OFF.
SwitchS5/2isnotrequiredontheleaderWallbox.
SettheswitchtoOFF.
Conguration as leader and follower via
switchS5/4
S5/4
ON Leader
OFF Follower
Conguration of blocking function (in leader
Wallbox) via switch S5/3
TheWallboxhasaninputviawhichitcanbe
blockedbyanexternalswitchingelement
(key-operatedswitchorsimilardevice;see
assemblyinstructions).
UseswitchS5/3tospecifywhetherthisblocking
istoaffectonlytheleaderWallboxorall
Wallboxes.
S5/3
OFF
OnlytheleaderWallbox
isblocked.
ON
AllWallboxesare
blocked.
4.5 Switch S6
TherstandlastdevicesontheRS485busmustbe
connected with a terminating resistor.
Terminating resistor for last Wallbox
UsemicroswitchS6/2toconnectthebuilt-intermi-
natingresistoronthelastfollowerWallbox.Switches
S6/1,S6/3andS6/4arenotused.Settheseswitches
to OFF position.
S6/2
OFF Bus termination inactive
ON Bus termination active
Local load management
Terminating resistor for leader Wallbox
UsemicroswitchS6/2toconnectthebuilt-intermi-
natingresistorontheleaderWallbox.SwitchesS6/1,
S6/3andS6/4arenotused.Settheseswitchesto
OFF position.
External load management
HEMS terminating resistor
Whenusinganexternalcontrolunit,terminate
thebuslinewitha120Ohmresistor.Observethe
specicationsfromthemanufactureroftheexternal
control system here.
5. Bus protocol
(external load management)
TheModbusRTUprotocolisusedforcommuni-
cationbetweentheexternalcontrolsystemand
theWallboxes.EachWallboxisreadytoreceivea
Modbuscommandonlyaftermorethan10seconds
haveelapsedsincePowerOn.Ifthecorresponding
Wallboxisinstandbymode,itcannotbeaddressed
viaModbus.
Leader Follower1 Follower2
RS485S6/2 S6/2
Follower3 Follower4
Leader
HEMS
Follower1 Follower2
RS485
120 Ohm S6/2
Follower3 Follower4 Follower5