Appendix C: Specifications
appendIx C: speCIfICaTIons
ALERT ZONES
Number of Zones: 12
Zone Connector: terminal block
Zone Types: N.O./N.C. contact, 2.8K Thermistor ( -109° to 115ºF, -85º to 57ºC ) And 10K Thermistor
(-87° to 168°F; -66° to 76°C), and 4-20mA (-80,000.0 to 80,000.0
Zone Characteristics: 28.7KΩ to 3.3V (temperature/contact) or 250 Ohms to ground (4-20mA)
A/D Converter Resolution: 12 bits ±2 LSB
Zone Protection: 5.5VDC Metal Oxide Varistor with fast acting diode clamps.
RELAY OUTPUT
Rated for 1A 30VAC/ 1A 30VDC Maximum
DATA LOGGING
5 minutes to 1 month sampling rate
User programmable channel selection
Zones 1 – 12
Battery
Input Power
LED INDICATORS
Power: On steady when the unit is powered on.
Alarm: Off when no alarm exists.
Ethernet Link and Activity LEDs
Online
Standby
COMMUNICATION TYPE:
10/100 BASE-T Ethernet with SSL encryption
POWER SUPPLY
Power Supply: 120VAC/12VDC 50/60Hz 6W wall plug-in transformer w/6’ cord.
Power Consumption: 2 Watts
Power Protection: Metal Oxide Varistor
Battery Backup: Internal 8 hr battery backup module (Part #BAT-0032).

Other manuals for Sensaphone Sentinel Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sensaphone Sentinel Pro and is the answer not in the manual?

Sensaphone Sentinel Pro Specifications

Power IconPower
power input voltage11.5 - 20 VDC
power input current350mA nominal/650mA peak
battery backup12V 3.4 AH
Operating Environment IconOperating Environment
operating temperature0° to 135°F (-18 to 57°C)
Weight and Dimensions IconWeight and Dimensions
enclosure dimensions14” x 12” x 7.4”
weight12 Lbs.