3-2 Programming
WRMTM-40001 iPERL Water Management System Technical Manual
3.2 Connecting the iPERL System to a PC
You will need an OMNI Communicator 100A and drivers to connect the iPERL system to your PC. To obtain
these tools, please see your Sensus representative. To connect the iPERL system to your PC:
1. Attach the USB connector from the OMNI Communicator 100A to any available USB port on your
PC.
2. Check your Device Manager to determine the USB port’s COM port settings.
3. Go to Start | Control Panel | System | Hardware | Device Manager.
4. Expand the Ports option to view the COM port assignment for the USB Serial Port.
5. In the Unipro application, click the Defaults menu option.
The Defaults screen appears, as shown in Figure 3-1.
Figure 3-1: Defaults Screen
6. Choose Connection Settings from the list.
Alarm Mask The types of alarms that will be recorded by the system. The
options are reboot, low battery, very low battery, configuration
error, empty pipe, magnetic tamper, reverse flow, leak, EMF
range, low battery volts, high temperature, flow field, high cur-
rent, glide slope, ADC failure, and touchread failure.
System Parameter Definition

Other manuals for Sensus iPerl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sensus iPerl and is the answer not in the manual?

Sensus iPerl Specifications

General IconGeneral
TypeUltrasonic water meter
Measurement TechnologyUltrasonic
Protection ClassIP68
MaterialComposite
Pressure Rating232 psi (16 bar)
CommunicationAMR/AMI Compatible
Battery Life20 years
Maximum Pressure16 bar
OutputPulse
Power SupplyBattery
Temperature RangeUp to 158°F (70°C)
Operating Temperature32°F to 158°F (0°C to 70°C)

Related product manuals