Specification
Doc. # 177/52701
Rev. 3.3
4-7
EMC
Radiated emissions:
EN12895 (Industrial Trucks Electromagnetic
Compatibility)
EN 55022:1998, 6, class B
EN 12895:2000, 4.1 Emissions. When part of a system with
a motor operating,
FCC Part 15, Radiated Emissions. Meets the standards
given in FCC Part 15, Section 15.109:
Conducted
emissions:
No mains port, therefore not required
Susceptibility:
Performance level A (no degradation of performance) or
level B (degradation of performance which is self-
recoverable) subject to the additional requirement that the
disturbances produced do not:
affect the driver’s direct control of the truck
affect the performance of safety related parts of the
truck or system
produce any incorrect signal that may cause the driver
to perform hazardous operations
cause speed changes outside limits specified in the
standard
cause a change of operating state
cause a change of stored data
Radiated RF field:
EN 61000-4-3, 5.1 Test Level: user-defined test level of 12
V/m
EN 12895:2000, 4.2 Immunity
EN 61000-4-6, Table 1 - Test Levels
Electrical fast
transient:
EN 61000-4-4, Table 1 - Test Levels, Level 2
Electrostatic
discharge:
EN 12895:2000, 4.2 Electrostatic Discharge
4 kV contact discharge
8 kV air discharge
Electrical surge:
EN 61000-4-5:1995, Table A.1 Selection of Test Levels,
Class 3
Regulatory compliance
Designed to meet:
EN1175-1:1998 (which covers EN1726 for the controller)
ISO 3691
UL583
ASME/ANSI B56.1:1993

Table of Contents