5
Mechanical installation
Assembly
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
51
Preparing the holding fixture
Square pipes can be used as a holding fixture for the device. To prevent mechanical
overlapping, use square pipes with an edge length of ≤32mm.
The following figure shows the required dimensions in mm:
M5
M5
115
M8
10
20
77.5 67.5
86.5
114.5
Ø15
Ø 6.6
40.5
M6
66
95 20
10
135
14.6
20
X
2
X
1
77.5 67.5 A
Y
A
Y
9007208941626891
X
1
, Y Housing dimensions
X
2
Bore dimension
A Distance
Procedure
ü For the housing dimensions X
1
and Y, refer to the dimension drawings in chapter
"Technical data"(→2164).
ü The bore dimension X
2
for the holding fixture bores can be derived from the hous-
ing dimension X
1
‑30mm.
ü The clearance dimension A of the holding fixtures can be derived from the housing
dimension Y‑145mm. Note that the distances are asymmetrical.
1. Mark the bore dimension X
2
for the holding fixture bores.
2. Mark the dimension A at the installation location.
3. Mount the holding fixture at the installation location at the calculated distance.
26596598/EN – 10/2020