Section 3
Emergency
Procedures
Doc. No.: SHARK600_MA_075
Voltmeter shows battery voltage.
Normal value is 12 to 13,5V.
Below 11V the battery is empty and
engine start is not possible.
Voltage is provided by the regulator.
Normal level is 13.5 – 14,4V.
If regulator fails, charging indicator starts
flashing, voltage drops below 10.5V,
some instruments stop working.
Engine running
Ammeter indicates negative
or zero values
With negative values
-15 to 0 Amps, battery is being charged.
0 shows fully charged battery.
Engine running
Ammeter indicates positive
values
Power is drained from battery. This
indicates a regulator failure.
Ammeter indicates a positive value,
indicating that electrical equipment
takes power from the battery.