EasyManua.ls Logo

Shark 600 - Page 52

Shark 600
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 3
Emergency
Procedures
FLIGHT MANUAL
SHARK 600
3-16
Doc. No.: SHARK600_MA_075
2024-02-25
Rev. B
2. Volt Meter
Condition
Engine not running
Voltmeter shows battery voltage.
Normal value is 12 to 13,5V.
Below 11V the battery is empty and
engine start is not possible.
Engine Running
Voltage is provided by the regulator.
Normal level is 13.5 14,4V.
If regulator fails, charging indicator starts
flashing, voltage drops below 10.5V,
some instruments stop working.
3. Ammeter
Condition
Engine running
Ammeter indicates negative
or zero values
With negative values
-15 to 0 Amps, battery is being charged.
0 shows fully charged battery.
Engine running
Ammeter indicates positive
values
Power is drained from battery. This
indicates a regulator failure.
Engine not Running
Ammeter indicates a positive value,
indicating that electrical equipment
takes power from the battery.