EasyManua.ls Logo

Shelly Wave Plug US User Manual

Shelly Wave Plug US
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Wave Plug US
Z-Wave® smart plug with power measurements
Extended User Guide (EN)
Device: Wave Plug US
USA Part number/Ordering Code: QNPL-001X16US
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0088
Z-Wave Manufacturer: Shelly Europe
Z-Wave Manufacturer ID: 0x0460

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shelly Wave Plug US and is the answer not in the manual?

Shelly Wave Plug US Specifications

General IconGeneral
Power supply120 V ±10 %, 60 Hz
Power consumption< 0.3 W
Power measurement [W]Yes
Max switching voltage AC140 V
Max switching current AC15 A
Overheating protectionYes
Overcurrent protectionYes
Overvoltage protectionYes
Distanceup to 40 m indoors (131 ft.) (Depends on local condition)
Shell materialPlastic
ColorWhite
Z-Wave repeater:Yes
Z-Wave frequencies band(s)908, 4
Maximum radio frequency power transmitted in frequency bend(s)< 25 mW
CPUZ-Wave S800
Compatible socketsNEMA 5-15 (Type-B)
Compatible plugsNEMA 1-15 (Type-A) and NEMA 5-15 (Type-B)
Ambient temperature-20°C to 40°C / -5°F to 105°F
Humidity30% to 70% RH
Max. altitude2000 m / 6562 ft.
Weight and Dimensions IconWeight and Dimensions
Size (H x W x D)38x84x52 ±0.5 mm / 1.5x3.3x2.0 in ±0.02 in
Weight70 ±1 g / 2.47 ±0.04 oz

Summary

User and Safety Guide

About the Device

Installation Instruction

Installation instruction

Details the installation of the smart plug for controlling appliances and measuring power.

About Z-Wave

Z-Wave Adding / Removing / Factory reset

Adding the Device to a Z-Wave network (inclusion)

Guides on how to add the device to a Z-Wave network via inclusion.

Adding (inclusion) with the S button

Explains how to add the device to a Z-Wave network using the S button.

Removing the Device from a Z-Wave network (exclusion)

Guides on how to remove the device from a Z-Wave network via exclusion.

Factory reset

Provides instructions for resetting the device to factory default settings.

Z-Wave Security 2 and Device Specific Key (DSK)

Z-Wave DSK label and QR code (example)

LED Signalization

Z-Wave Parameters

Parameter No. 17 - Restore the O (01) state after a power failure

Configures whether the device saves and restores the last ON/OFF state after a power failure.

Parameter No. 19 - O (O1) Auto OFF with timer

Sets a timer for the device to automatically turn OFF the load after a specified period.

Parameter No. 20 - O (O1) Auto ON with timer

Sets a timer for the device to automatically turn ON the load after a specified period.

Parameter No. 23 - O (O1) contact type - NO/NC

Determines the relay contact type for output O (01) as normally open (NO) or normally closed (NC).

Parameter No. 25 - Set timer units to s or ms for O (01)

Specifies whether timers for parameters 19 and 20 use seconds or milliseconds.

Parameter No. 36 - O (O1) Power report on change - percentage

Sets the minimum power change percentage to trigger a report to the gateway.

Parameter No. 39 - Minimum time between reports (O) 01

Determines the minimum time interval between sending power reports to the gateway.

Parameter No. 91 - Water Alarm

Configures the device's response to water alarm notifications.

Parameter No. 92 - Smoke Alarm

Configures the device's response to smoke alarm notifications.

Parameter No. 93 - CO Alarm

Configures the device's response to carbon monoxide (CO) alarm notifications.

Parameter No. 94 - Heat Alarm

Configures the device's response to heat alarm notifications.

Parameter No. 117 - Remote Device reboot

Enables remote rebooting of the device for troubleshooting purposes.

Z-Wave Command Class

Z-Wave Notifications Command class

Z-Wave Associations

Technical Specifications