12. Z-Wave Notifications Command class
Z-Wave
Notification
Type Name
LED
colour
status
Device
reaction
Action to
restore
Device
specific
Z-Wave
definition
12.1 Overheat detected
Heat
Alarm
Overheat
detected
Check the
RGB LED
signalization
table
Switch OFF
all outputs
and send a
notification
Any of the following
activities reset this
alarm: power cycle,
Remote Device
reboot (with
Parameter No. 117),
short press on the S
button, press on any
switch/push-button
connected to any SW
(SW, SW1, SW2, …)
terminal.
YES
notification
type=heat alarm
Value=0x04,
event=State
Notification
name=Overheat
detected
Value=0x02,
Version=V2
12.2 Overcurrent detected O
Power
Management
Overcurrent
detected O
(O1)
Check the
RGB LED
signalization
table
Switch OFF
the output
O (O1) and
send a
notification
Any of the
following
activities reset
this alarm:
power cycle,
Remote Device
reboot (with
Parameter No.
117), short
press on the S
button, press on
any
switch/push-
button
connected to
any SW (SW,
SW1, SW2, …)
terminal.
YES
notification
type=power
management
Value=0x08.
event=State
Notification
name=Over-
current
detected
Value=0x06,
Version=V3