EN.
19
Parameter No. 94 - Heat Alarm
This parameter determines how the device should respond to the reports of alarm frames. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
The notification types it reacts to are as followed,
Notification Type:
- NOTIFICATION_TYPE_HEAT_ALARM 0x04
Notification Events:
- NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_RISE_LOCATION_PROVIDED 0x03
- NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_RISE 0x04
- NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_FALL_LOCATION_PROVIDED 0x0C
- NOTIFICATION_EVENT_HEAT_ALARM_RAPID_TEMPERATURE_FALL 0x0D
Values size: 4 Byte
Default value: 0
Values & descriptions:
• 0 no action
• 1 open relay
• 2 close relay
Parameter No. 117 - Remote Device reboot
This parameter enable restarting or rebooting the Device without physical intervention. Use this
parameter only for troubleshooting scope. After device reboot value will be set to default
Values size: 1 Byte
Default value: 0
Values & descriptions:
• 0 - function inactive
• 1 - Remote device reboot
Parameter No. 120 - Factory Reset
Reset to factory default settings and removed from the Z-Wave network.