17
be sent more frequently than defined by Parameter No. 39.
Parameter No. 39 - Minimum time between reports (O) O1
This parameter determines the minimum time that must elapse before a new power report on
O (O1) is sent to the gateway.
Values size: 1 Byte
Default value: 30
Values & descriptions:
0 - reports are disabled
1-120 (1-120s) - report interval
NOTE: This Parameter is in relation to Parameter No. 36.
NOTE: Setting the value to less than 30s can cause the Z-Wave network congestion state (slow
Device response and decreased network stability).
Parameter No. 91 - Water Alarm
This parameter determines how the device should respond to the reports of alarm frames. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
The notification types it reacts to are as followed,
Notification Type:
- NOTIFICATION_TYPE_WATER_ALARM 0x05
Notification Events:
- All except ALARM_NO_EVENT 0x00
Values size: 4 Byte
Default value: 0
Values & descriptions:
• 0 no action
• 1 open relay
• 2 close relay