3) Now pressing can alter value, press ENTER to input after confirming
then jump to F-07.
4) If you want to leave the function setting, just press SET.
1. F-06 stands for the passwords of second level.
2. F-07 stands for proportional band of heating side (P); it is a preset value
before delivery.
3. F-08 stands for integration time of heating side (I); it is a preset value before
delivery.
4. F-09 stands for differential time of heating side (D); it is a preset value before
delivery.
5. F-10 stands for switch cycle of heating side; its preset value is 15 sec.
6. F-16 stands for power deliver delay time of heater, it is adjustable, the unit is
Sec..
7. F-17 stands for blower power-off delay time, it is adjustable, the unit is Sec..
8. F-18 stands for the protection of maximum temperature. Its setting range is
140~250.
9. F-19 stands for microswitch timeset of honeycomb rotor. OFF functions as
shut-off and ON functions as open. The setting range is 0~9999 with the
unit is Sec..