6.4 Clean of Y type strainer
The cleaning work should be done according to the condition of cooling water
dust. Clean it in time in such situations, such as hot air and insufficient cooling
water flow.
6.5 Maintenance Schedule
6.5.1 General Machine Information
Model SN Manufacture date
Voltage Ф V Frequency Hz Power kW
6.5.2 Check After Installation
Check that pipe connections are firmed locked by clips.
Check that the piping system is correct.
Check if the honeycomb-rotor is damaged or not.
Electrical Installation
Voltage: V Hz
Fuse melt current:1 Phase A 3 Phases A
Check phase sequence of the power supply.
Check the rotating direction of blower fans.
6.5.3 Daily Checking
Check power supply wires.
Check the start/stop function.
Check the temperature controller.
Clean the filter.
Check whether overheat protection is normal.
Check whether dew-point is normal.
Check whether cooling water circulation and Y-type fitter are normal
1
.
6.5.4 Weekly Checking
Check if there are loose connections of electrical components.
Check and clean air filter.
Check the function of solenoid valve.
Check motor overload relay and anti-phase function.