Check whether air pipe is shed, leaked and loose.
6.5.5 Monthly Checking
Check if the transmission belt is loose or not.
Check the performance of gear motor.
Check if there are leakages in honeycomb-rotor.
6.5.6 Half-yearly Checking
Check if there are damages of heat-resistant hoses.
Check the pipe heaters.
Check regen./process blower and blower fans.
Check whether honey-comb rotor belt is damaged.
Clean the cooler.
6.5.7 Yearly Checking
Check whether the contactor is normal
2
.
6.5.8 3 year Checking
PC board renewal.
No fuse breaker renewal.
Note: 1. Y-type filter has the function of filling water cooling protection effect, be sure the
waterway are clear to avoid cooling failure.
2. Manufacturer laboratory data for AC contactor is two million times in life. we suggest
service life for one million four hundred thousand times, if work eight hours per day,
recommended replacing frequency is 1.5 years, if work day and night, replacement is
suggested to be done every six months.