Troubles Possible causes Solutions
1. Problems of rotor motor. 1. Check or replace the motor.
2. Rotor belt broken. 2. Replace the belt.
3. Problems of electrical circuit.
3. Check the electrical circuit.
4. Micro switch of the rotor
failures.
4. Replace.
E-09 is shown at PV,
buzzer sounds and
machine stops
5. Parameter mistakes of timer
for control of rotor.
5. Reset the timer. (Set time should be
bigger than rotor rotating time in one
turn and plus 1 minute.)
1. Too short of time since start
of the machine.
1. Wait for a while.
Abnormal temp.
fluctuations.
2. Improper parameters for
temp. controller.
2. Check the parameters of temp.
Controller.
1. Temp. Setting is too high. 1. Set heater temp. under 180.
2. Contactor of heater is bad. 2. Replace contactor.
3. Pipe heater is damaged. 3. Replace pipe heater.
4. Problems of thermocouple. 4. Replace thermocouple.
5. Parameter of temp. controller
is set to STOP.
5. Set temp. controller under working
mode.
Heater temp. can not
rise up.
6. Temp. controller output
problems.
6. Replace or repair temp. controller.
1. Short circuits of main circuit.
1. Check the circuit.
2. Short circuit of transformer. 2. Replace the breaker.
Breaker tripping off
when connects with
power supply.
3. Problems of breaker. 3. Replace the breaker.
1. Short circuit of pipe heater. 4. Check the circuit.
Circuit breaker trips
right after system
switch on.
2. Problems of the breaker. 5. Replace the breaker.